HomeMy WebLinkAbout2011-05-26 Summit Fire Protection Report of Inspection A SUMMIT ii' PROT1wrION 575 MINNEHAHAAVE. W • ST. PAUL, MN 55103 • (651) 251 -1880 3026 40TH AVE. NW • ROCHESTER, MN 55901 • (507) 280-0622 .418,6REA' AK DR, WAITE PARK, MN 56387 320) 257 -6390 760 LIBERTY WAY, 1 R'1 1`Y, IA 52317 • (319) 665 -4330 4208 ENTERPRISE CIRCLE • DULUTH, MN 55811 • (218) 740-4412 SHEET 1 OF 2 - Use separate sheet for each building inspection G 07 REPORT OF INSPECTION MINNESOTA LICENSE NO. C0075 JOB NUMBER e r� l n ST7 INSPECTION NAME pl air BUILDING/LOCATION. • STREET , SS keufG t , L INSPECTOR ' P412,4 / CITY & STATE QAIr iQ J�IF CSC /�/ DATE 5 Owner's Section (to be answered by Owner or Occupant) A. Explain any occupancy hazard changes since the previous inspection: B. Describe fire protection modifications made since last inspection: o C. Describe any fires since last inspection: D. When was the system piping last checked for stoppage, corrosion of foreign material? 7 E. When was the dry- piping system last checked for proper pitch? M 14;,, , J Are dry valves adequately protected from freezing? f Signature /�' Title ! . � - Date . j " l [ Inspector's Section (All responses reference current inspection) NA =NOT APPLICABLE 1. General a. Is the building occupied ?Wes 0 No b. Are all systems in service,#'es 0 No c. Is there a minimum of 18 in. (457 mm) clearance between the top of the storage and the sprinkler deflectors? James 0 No d. Does all electrical heat tape appear to be satisfactory? UYes 0 No libNA e. Does the hand hose or standpipe on the sprinkler system(s) appear to be satisfactory? OYes 0 NotA 2. Control Valves (See Item 15.) a. Are all sprinkler system control valves and all other valves in the • • • priate a . � • closed position? O No b. Are Id/control valves m the iochot& or ' Lr ; ' With q,.:: v vti.�= - > • r ' ;f a en ` o�� a dig :.. a. When was fire pump last tested for performance? • b. Are fire pumps, gravity tanks, reservoirs and pressure tanks in good condition and properly maintained? UYes 0 NoyiklNA c. Are fire department connections in satisfactory condition, couplings free, caps in place, and check valves tight? 0 No 0 NA Are they accessible and visible ?,Yes 0 No 0 NA 4. Wet Systems a. Are cold weather valves (O.S. & Y.) in the appropriate open or closed position? OYes 0 N94A b. Have antifreeze system solu been tested? ❑Yes ❑ No uNA c. What temp is antifreeze? d. In areas protected by wet system(s), does the build pea be properly heated in all areas, including blind attics and perimeter areas '' where accessible s 0 No O NA 5. Dry System (Se Items 11 to 13) a. Are dry valve(s) in service? UYes 0 No 0 NA b. Are the air pressures and priming water levels in accordance with the manufacturer's instructions? UYes 0 No 0 NA c. Has the operation of the air • 1'trQ: n supplies been tested? UYes 0 No 0 NA Are they in service? UYes 0 No 0 NA d. Were low points drained d •11 - • - - lion? UYes 0 No 0 NA How many? e. Did quick - opening devices 'r a y? OYes 0 No ' 0 NA f. Did the dry valve(s) trip p . _; T e,trip pressure test? UYes ❑ No 0 NA g. Did the heating equipm in ..: • - • . • - valve room(s) operate at time of inspection ? UYes 0 No ❑ NA 6. Special Systems (See. Item 14.) a. Did the deluge or pre- action valves operate properly during testing? ❑Yes 0 No 0 NA b. Did the heat - responsive de • • l. , properly during testing? OYes 0 No UNA c. Did supervisory devices o • ? testing? OYes 0 No 0 NA d. Did flow for kitchen hood y w • 1 .117 off gas or electric? OYes 0 No 0 NA 7. Alarms a. Did water motor(s) and gong(s) test satisfactorily? OYes ❑ No JIA b. Did electric alarm(s) test satisfactorily? At Fes 0 No 0 NA At r Did supervisory alarm service test satisfactorily? g31'es 0 No CI NA !'�+" .. d. Did tamper switches test satisfactorily? Iirles 0 No 0 NA 8. Sprinklers a. Are all sprinklers free from corrosion, loading or obstruction to spray discharge? tiffes ❑ No b. Are sprinklers less than 50 years old? (Older sprinklers require sample testing) Wes ONo c. Are quick response and residential spri less than 20 years old? (Older sprinklers require sample testing Yes 0 No d. Is stock of spare y.,: . ers available? Mres 0 No e. Does the ex - • con., lion of sprinkler system appear to be satisfactory? Wes ❑ No f. Are '1 of pro! temperature rating for thsir locations? littes 0 No g. Are any •1 . er h n a recall list? 0'es Wio Si a rf jai ' ` i ` r Date; 6 .. Y_ l am $ t 3 - - SUMMIT FI LE ' PRO' 575 Minnehaha Ave. W. • St. Paul, MN 55103 • 651 -251 -1880 3026 40th Ave. NW • Rochester, MN 55901 • 507- 280 -0622 418 Gloat O d r. • Waite Park, MN 56387 • 320-2574390 760 Liberty Way • North Liberty, IA 52317 • 319 - 665 -4330 w 08 Enterprise Circle • Duluth, MN 55811 • 218 - 740 -4412 ,_l / 2 OF 2 - Use separate sheet for system"' ection Type of System w pection Name P!£ ONE . AK N/7 How Many? Inspection Work Order q What Size? .5 . ow ./ . I arm Check with Pressure Switch 9. Date dry-pipe valve trip tested (control valve partially open) (see Trip Test Table which follows) 10. Date dry-pipe valve trip tested (control valve fully open) (see Trip Test Table which follows) 11. Date quick - opening device tested (see Trip Test Table which follows) DRY VALVE '; TRIP TEST TABLE Q.O.D. MAKE MO t ' NO. MAKE MODEL SERIAL NO. DRY PIPE Mu to Trip Wate Press Air Pressure Trip Point Time Wate Reached Al arm Operated OPERATING u TestPipe Air Pressure Test Outlet Properly TEST Min. Sec. . PSI PSI ,PSI - Min. Sec. Yes.. No Without Q.O.D. With 0.0.D. I 12. Date deluge or preacdon valve tested 1 /tJ / (see Trip Test Table which follows) / TRIP TEST TABLE .- Operation ` ❑ Pneumatic ❑ El- . ' ❑ Hydra Piping Supervised ❑ Yes ❑ No Detecting Media Supervised ❑ Yes ❑ No D E L U G E & Does valve operate f r o m the manual trip and/or r e m o t e c o n t r o l .. " ? ❑ Yes ❑ No PREACTION � VALVES is there an accessible facility in each circ . testing? ❑ Yes • . Method of Testing Circuits: MAKE MODEL r • Each Circuit Operate Does Each Circuit Max um Tune to Supervision Loss Alarm? Operate Valve Release? Operate Release? 13. See Control Valve Maintenance Table CONTROL VALVE MAINTENANCE TABLE CONTROL VALVES NUMBER SIZE & TYPE OPEN SECURED CLOSED SIGNS EXPLAIN ABNORMAL CONDITIONS City Connection Control Valve • 0 J. ,�-�` 4.......1i, .+tom Jockey Control Valve Pump Control Valves S Additional Pump Control Valves Test Header Sectional Control Valves System Control Valves J jog,- 7 __....... t Other Control Valves i k, (5 ,, S Kitchen Control Valves Water Flow Test at Sprinkler ' Water Supply Source: ' City Well Tank Pump DATE TEST PIPE LOCATION SIZE OF TEST PIPE sTATiC '' r RESIDUAL (ELDW D Last Water Flow Test / 9 0,4 02M .. f / 7 This Water Flow Test �willi db. r liir 14. Explain any "No" answers and comments: _ .. " ' ' , . --, Print Name Si a . :..: - a� - Date