Loading...
HomeMy WebLinkAbout2005 Inspection Ticket and Notes - Multiple Permits ti � Jim Butler Subject: " Final Addition & Fireplace Location: 14240 57th St. N. Start: Tue 2/21/2006 4:00 PM End: Tue 2/21/2006 4:30 PM Recurrence: (none) Paul Price - Homeowner. Someone will be there to permit you access. Work Number: 251 -9286 CeII Number: 612 - 940 -8460 Permit # 05 -163 for a driveway PASS Permit # 05 -193 for a fireplace PASS Permit # 05 -015 for the addition 1) PASS PENDING FINAL ELECTRICAL INSPECTION 2) * ** PER SECTION R312.1.1 LANDINGS FOR STAIRWAYS. THERE SHALL BE A FLOOR OR LANDING AT THE TOP AND BOTTOM OF EACH STARIWAY. EXCEPTION: AT THE TOP OF AN INTERIOR FLIGHT OF STAIRS, PROVIDED A DOOR DOES NOT SWING OVER THE STAIRS. R312.2 SIZE THE DOOR SHOULD BE REMOVED OR A LANDING INSTALLED. WITH YOUR C. 0. I HAVE ENCLOSED A COPY OF THE CODE SECTION. CALL ME SHOULD YOU HAVE ANY QUESTIONS. 1 R311.2 - R314.4 BUILDING PLANNING the habitable portions of the dwelling to the exterior without re- 3. Where ramps change direction. quiring travel through a garage. R311.2 Type of lock or latch. All egress doors shall be readily SECTION 8314 openable from the side from which egress is to be made without the use of a key or special knowledge or effort. STAIRWAYS R311.3 Type and size. The required exit door shall be a side- R314.1 Width. Stairways shall not be less than 36 inches (914 hinged door not less than 3 feet (914 mm) in width and 6 feet, 8 mm) in clear width at all points above the permitted handrail inches (2032 mm) in height. Other exterior hinged or sliding height and below the required headroom height. Handrails doors shall not be required to comply with these minimum di- shall not project more than 4.5 inches (114 mm) on either side mensions. of the stairway and the minimum clear width of the stairway at and below the handrail height, including treads and landings, R311.4 Hallways. The minimum width of a hallway shall be shall not be less than 31.5 inches (787 mm) where a handrail is not less than 3 feet (914 mm). installed on one side and 27 inches (686 mm) where handrails R311.5 Exit facilities. Exterior exit balconies, stairs and simi- are provided on both sides. lar exit facilities shall be positively anchored to the primary Exception: The width of spiral stairways shall be in accor- structure to resist both vertical and lateral forces. Such attach- dance with Section R314.5. ment shall not be accomplished by use of toenails or nails sub- ject to withdrawal. R314.2 Treads and risers. The maximum riser height shall be 7 inches (196 mm) and the minimum tread depth shall be10 inches (254 mm). The riser height shall be measured vertically SECTION R312 between leading edges of the adjacent treads. The tread depth LANDINGS shall be measured horizontally between the vertical planes of R312.1 General. Landings for stairways shall comply with the foremost projection of adjacent treads and at a right angle to R3 83 ction Ge the tread's leading edge. The walking surface of treads and thi landings of a stairway shall be sloped no steeper than one unit R 312.1.1 Landings for stairways. There shall be a floor or vertical in 48 units horizontal (2- percent slope). The greatest l anding at the top and bottom of each stairway. Exception: At the top of an interior flight of stairs, pro- riser height within any flight of stairs shall not exceed the smallest by more than 3 / 8 inch (9.5 mm). The greatest tread vided a door does not swing over the stairs. depth within any flight of stairs shall not exceed the smallest by more than / inch (9.5 mm). R312.1.2 Landings at doors. There shall be a floor or land- ing on each side of each exterior door. R314.2.1 Profile. The radius of curvature at the leading edge of the tread shall be no greater than /16 inch (14.3 mm). Exception: At the exterior side of sliding doors. A nosing not less than 3 / 4 inch (19.1 mm) but not more The floor or landing at a door shall not be more than 1.5 thanl V inches (32 mm) shall be provided on stairways with inches (38 mm) lower than the top of the threshold. solid risers. The greatest nosing projection shall not exceed the smallest nosing projection by more than 3 / 8 inch (9.5 Exception: The landing at an exterior doorway shall not mm) between two stories, including the nosing at the level of be more than 8 inches (197 mm) below the top of the floors and landings. Beveling of nosing shall not exceed V threshold, provided that the door, other than an exterior inch (12.7 mm). Risers shall be vertical or sloped from the storm or screen door, does not swing over the landing. underside of the leading edge of the tread above at an angle R312.2 Size. The width of each landing shall not be less than not more than 30 degrees from the vertical. Open risers are the stairway or door served. Every landing shall have a mini- permitted, provided that the opening between treads does mu m dimension of 36 inches (914 mm) measured in the direc- not permit the passage of a 4-inch-diameter (102 mm) tion of travel. _ ) sphere. Exceptions: SECTION R313 1. A nosing is not required where the tread depth is a RAMPS minimum of 11 inches (279 mm). R313.1 Maximum slope. Ramps shall have a maximum slope 2. The opening between adjacent treads is not limited of one unit vertical in eight units horizontal (12.5- percent on stairs with a total rise of 30 inches (762 mm) or slope). less. R313.2 Handrails required. Handrails shall be provided on at R314.3 Headroom. The minimum headroom in all parts of the least one side of all ramps exceeding a slope of one unit vertical stairway shall not be less than 6 feet, 8 inches (2032 mm) mea- in 12 units horizontal (8.33- percent slope). cured vertically from the sloped plane adjoining the tread nos- ing or from the floor surface of the landing or platform. R313.3 Landing required. A minimum 3- foot -by -3 -foot (914 mm by 914 mm) landing shall be provided: R314.4 Winders. Winders are permitted, provided that the width of the tread at a point not more than 12 inches (305 mm) 1. At the top and bottom of ramps. from the side where the treads are narrower is not less than 10 2. Where doors open onto ramps. inches (254 mm) and the minimum width of any tread is not less 48 2000 INTERNATIONAL RESIDENTIAL CODE®