Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2004-11-30 Viking Automatic Sprinkler Co. Report of Inspection
1301 L' NT STREET ST. P . NESOTA 55117 (651) 55o -3300 • (800)- 229 -6263 AUTOMATIC SPRINKLER CO. FAX: (651) 558 -3310 SHEET1OF2 -Uses separate sheet for each building inspection REPORT OF INSPECTION MINNESOTA LICENSE NO. C00005 WISCONSIN LICENSE NO. 265989 REPORT TO ©y4< R% c Phi re C BUILDING OR LOCATION Prt STREET 1 00 (a 0 -- C) )( k k° /1►.� r Al. INSPECTOR 1 i I1P.1 r CITY & STATE ©fir 1t P Nr. I -F s , VV■ . DATE 1 , — 3 t) — o1 Owner's Section (To be answered by Owner or Occupant) A. Explain any occupancy hazard changes since the previous inspection: B. Describe fire protection modifications made since last inspection. C. Describe any fires since last inspection. D. When was the system piping last checked for stoppage, corrosion or foreign material? E. When was the dry piping system last checked for proper pitch? F. "Are dry valves adequately protected from freezing? Signature Title Date Inspector's Section (All responses reference current inspection) NA =NOT APPLICABLE 1. General a. Is the building occupied ? ❑ No b. Are all systems in service ?..81res ❑ No c. Is there a minimum of 18 in. (457 mm) clearance between the top of the storage and the sprinkler deflectors? r C].d'es ❑ No d. Does all electrical heat tape appear to be satisfactory? ❑ Yes ❑ No J NA e. Does the hand hose on the sprinkler system(s) appear to be satisfactory? ❑ Yes ❑ No. J-NA 2. Control Valves (See Item 15.) a. Are all sprinkler system control valves and all other valves in the appropriate open or closed position ?Yes ❑ No b. Are all control valves in the open position locked, sealed or equipped with a tamper switch ? ••es ❑ No 3. Water Supplies (See Item 16.) a. Was a water flow test of main drain made at the sprinkler riser(s)? B'Yes ❑ No 4. Tanks, Pumps, Fire Department Connections a. Are fire pumps, gravity tanks, reservoirs and pressure tanks in good condition and properly maintained? ❑ Yes ❑ No L .NA b. Are fire department connections in satisfactory condition, couplings free, caps in place, and check valves tight? GJl'es ❑ No ❑ NA Are they accessible and visible? B'Yes ❑ No ❑ NA 5. Wet Systems a. Are cold weather valves (O.S. & Y.) in the appropriate open or closed position? ❑ Yes ❑ No .NA b. Have antifreeze system solutions been tested? ❑ Yes ❑ No ❑'1'IA c. Were the antifreeze test results satisfactory? ❑ Yes ❑ No ..NA d. In areas protected by wet system(s), does the building appear to be properly heated in all areas, including blind attics and perimeter areas where accessible? QrYes ❑ No ❑ NA Do all exterior openings appear to be protected against freezing ?"Yes ❑ No ❑ NA 6. Dry System (See Items 11 to 13.) a. Are dry valve(s) in service?. Yes ❑ No ❑ NA b. Are the air pressures and priming water levels in accordance with the manufacturer's instructions ?_ s'es ❑ No ❑ NA c. Has the operation of the air or nitrogen supplies been tested? ❑ Yes ❑ No . NA Are they in service? ❑ Yes ❑ No [A d. Were low points drained during this inspection? ❑ Yes ❑ No ANA e. Did quick - opening devices operate satisfactorily? ❑ Yes ❑ No j,e'NA f. Did the dry valve(s) trip properly during the trip pressure test ?,,,B Yes ❑ No ❑ NA g. Did the heating equipment in the dry-pipe value room(s) operate at time of inspection ? fe "Yes ❑ No ❑ NA 7. Special Systems (See Item 14.) a. Did the deluge or pre -action valves operate properly during testing? ❑ Yes ❑ No LktIA a b. Did the heat - responsive devices operate properly during testing? ❑ Yes ❑ No ['NA c. Did supervisory devices operate during testing? ❑ Yes ❑ No 1 8. Alarms a. Did water motor(s) and gong(s) test satisfactorily? ❑ Yes ❑ No [..i.1QA JAN ^ nnr b. Did electric alarm(s) test satisfactory? 'Yes ❑ No ❑ NA c. Did supervisory alarm service test satisfactory? l;InYes ❑ No ❑ NA 9. Sprinklers a. Are all sprinklers free from corrosion, loading or obstruction to spray discharge ?Jd Yes ❑ No b. Are sprinklers less than 50 years old? (Older sprinklers require sample testing) J4■Yes ❑ No c. Are quick response and residential sprinklers less than 20 years old? (Older sprinklers require sample testing) ❑ Yes ❑ No d. Is stock of spare sprinklers available? EYes ❑ No e. Does the exterior condition of sprinkler system appear to be satisfactory ? B'Yes ❑ No f. Are sprinklers of proper temperature rating for their locations? WYes ❑ No 10. Explain any "No" answer and comments: Signature: " Date: 1 -30 - 1301, 'RIENT STREET ik` AI G ST. 1 J MINNESOTA 55117 (651) 558 -3300 • (800)- 229 -6263 AUTOMATIC SPRINKLER CO. FAX: (651) 558 -3310 SHEET 2 OF 2 - Use separate sheet for each system inspection System No. Descr tion if multiple / systems et Inspection Report "I wit {- No. 11. Date dry-pipe valve trip tested (control valve partially open) (See Trip Test Table which follows) 12. Date dry-pipe valve trip tested (control valve fully open) (See Trip Test Table which follows) 13. Date quick - opening device tested (See Trip Test Table which follows) DRY VALVE TRIP TEST TABLE Q.O.D. MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. DRY PIPE Time to Trip Water Air Trip Point Time Water Reached Alarm Operated OPERATING Thru Test Pipe Pressure pressure Air Pressure Test Outlet Property TEST MIN. SEC. PSI PSI PSI MIN. SEC. YES NO Without Q.O.D. With Q.O.D. 14. Date deluge or preaction valve tested (See Trip Test Table which follows) TRIP TEST TABLE Operation ❑ PNEUMATIC ❑ ELECTRIC ❑ HYDRAULIC Piping Supervised ❑ YES ❑ NO I Detecting media supervised ❑ YES ❑ NO DELUGE & Does valve operate from the manual trip and/or remote control stations ❑ YES ❑ NO PREACTION Is there an accessible facility in each circuit for testing Method of testing - circuits VALVES ❑ YES ❑ NO Does each circuit operate Does each circuit Maximum time to MAKE MODEL supervision loss alarm operate valve release operate release YES NO YES NO YES NO 15. See Control Valve Maintenance Table. Control Valve Maintenance Table Explain Abnormal Control Valves Number Type Open Secured Closed Signs Condition City Connection Control ' _ 6" O S tt Valve Tank Control Valves Pump Control Valves Sectional Control Valves System Control Valves 1 - ‘4" %3 , F , "'rrq 1 Cithekontrol Valves 1 " (" Ii! 4.4 �- "' --- Kitchen Control Valve - Z a � 1! J q IBC "' — 16. Water Flow Test at Sprinkler Riser Water Supply Source: City Tank Pump Date Test Pipe Size of Static Residual Location Test Pipe Pressure (Flow) Pressure Last Water Flow Test This Water Flow Test 1 1 - 30-0 y i Z. %cf C r 1 � 4 C 7 n 7 S 17. Explain any "No" answers and comments: re C G \\ \eltu d p .e 1 fl V C k 1 { cl,,Pti 1-400 ,4. a 13 a 1\ no* L.',S } —a t ?›,,,%% Wi n c., t S .L—• o ..% 4-r A St <-1. .14e..... 18. Adjustments or corrections made during this inspection: 19. Although these comments are not the result of an engineering review, the following desirable improvements are recommended: p..., Signature: ,� Date: ' 1 3o -o.-1 1301 L' ORIENT STREET I Ill47 G ST. V , MINNESOTA 55117 (651) J -3300 • (800)- 229 -6263 AUTOMATIC SPRINKLER CO. FAX: (651) 558 -3310 SHE1 T 2 OF 2 - Use separate sheet for each system inspection System No. or Description if multiple systems Z 0.6, 3 Inspection Report L4" c . No. 11. Date dry-pipe valve trip tested (control valve partially open) (See Trip Test Table which follows) 12. Date dry-pipe valve trip tested (control valve fully open) (See Trip Test Table which follows) 13. Date quick - opening device tested (See Trip Test Table which follows) DRY VALVE TRIP TEST TABLE Q.O.D. MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. DRY PIPE Time to Trip Water Air Trip Point Time Water Reached Alarm Operated OPERATING Thru Test Pipe Pressure pressure Air Pressure Test Outlet Propery TEST MIN. SEC. PSI PSI PSI MIN. SEC. YES NO Without / /' O.O.D. / 9d 4t) b With O.O.D. 14. Date deluge or preaction valve tested (See Trip Test Table which follows) TRIP TEST TABLE Operation ❑ PNEUMATIC ❑ ELECTRIC ❑ HYDRAULIC Piping Supervised ❑ YES ❑ NO I Detecting media supervised ❑ YES ❑ NO DELUGE & Does valve operate from the manual trip and/or remote control stations ❑ YES ❑ NO PREACTION Is there an accessible facility in each circuit for testing Method of testing - circuits 114 VALVES ❑ YES ❑ NO Does each circuit operate Does each circuit Maximum time to MAKE MODEL supervision loss alarm operate valve release operate release YES NO YES NO YES NO 15. See Control Valve Maintenance Table. Control Valve Maintenance Table Explain Abnormal Control Valves Number Type Open Secured Closed Signs Condition City Connection Control Valve Tank Control Valves Pump Control Valves Sectional Control Valves 1 _^ System Control Valves 1 y 6 r F Other Control Valves Kitchen Control Valve , 16. Water Flow Test at Sprinkler Riser Water Supply Source: City Tank Pump Date Test Pipe Size of Static Residual Location Test Pipe Pressure (Flow) Pressure Last Water Flow Test This Water Flow Test J1 - -o4 14‘,4r. yq" 3 " 14‘,4r. 90 - 7 S . Lie t � ` 17. Explain any "No" answers and comments: 5...m. 1e @ Fa e f `►c Cra S ks- }' C\a plat TSke_+ on J' 5►(Pe Ikc (w kei II Jr ;4\ slow cl r► p 6 t.,-1- -}tlPrc . 18. Adjustments or corrections made during this inspection: 19. AlthougU compe are not the result of an engineering review, the following de irable improvements are recommended: c}r a P t l c k. Signature: , ' L 7 Date: 1 \ • 3 a ^ Oq 1301" STREET 7iNIal 0 ST.. MINNESOTA 55117 (651) 558 -3300 • (800)- 229 -6263 - A UTOMATIC SPRINKLER CO. FAX: (651) 558 -3310 SHEET 2 OF 2 - Use separate sheet for each system inspection System No. or Description if multiple systems 3 01, 3 Inspection Report b S fl No. 11. Date dry-pipe valve trip tested (control valve partially open) (See Trip Test Table which follows) 12. Date dry-pipe valve trip tested (control valve fully open) (See Trip Test Table which follows) 13. Date quick - opening device tested (See Trip Test Table which follows) DRY VALVE TRIP TEST TABLE Q.O.D. MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. DRY PIPE Time to Trip Water Air Trip Point Time Water Reached Alarm Operated OPERATING Thru Test Pipe Pressure pressure Air Pressure Test Outlet Properly TEST MIN. SEC. PSI PSI PSI MIN. SEC. YES NO Without Q.O.D. With Q.O.D. 14. Date deluge or preaction valve tested (See Trip Test Table which follows) TRIP TEST TABLE Operation ❑ PNEUMATIC ❑ ELECTRIC ❑ HYDRAULIC Piping Supervised ❑ YES ❑ NO I Detecting media supervised ❑ YES ❑ NO DELUGE & Does valve operate from the manual trip and/or remote control stations ❑ YES ❑ NO PREACTION Is there an accessible facility in each circuit for testing Method of testing- circuits VALVES ❑ YES ❑ NO Does each circuit operate Does each circuit Maximum time to MAKE MODEL supervision loss alarm operate valve release operate release YES NO YES NO YES NO 15. See Control Valve Maintenance Table. Control Valve Maintenance Table Explain Abnormal Control Valves Number Type Open Secured Closed Signs Condition City Connection Control Valve Tank Control Valves Pump Control Valves Sectional Control Valves ?j_ 40, a, F System Control Valves 1_ 6 r g r F Other Control Valves Kitchen Control Valve 16. Water Flow Test at Sprinkler Riser Water Supply Source: City Tank Pump Date Test Pipe Size of Static Residual Location Test Pipe Pressure (Flow) Pressure Last Water Flow Test This Water Flow Test )1- 2 ) 15 - 04 R,.5•41- itt P. ' y 8 S , 17. Explain any "No" answers and comments: 1,-,c) P `p ' Sw ► _1,-. ( is 1 fir . A O i" rP��1J - PJ A (ee o t.„nlPµ .3 •d. 18. Adjustments or corrections made during this inspection: • 19. Although these comments are not the result of an engineering review, the following desirable improvements are recommended: p,,k___, Signature: Date: ° 1 / - 3a - d t