HomeMy WebLinkAbout1993-11-23 Viking Automatic Sprinkler Co. Report of Inspection SHEET 1 OF 2 - Use separate sheet tor each building inspection. 2/-(. -_-
1 tow Report No. REPORT OF INSPECTION e lection Contract No.
Conferred With .eau File No.
REPORT TO +�` VC'a� � � BUILDING OR LOCATION �
STREET 0 • ♦ . o INSPECTOR „ 1
CITY & STATE ( (e— = C 1:14-114/4 � /V. DATE 1 1 ( 1 3
Owner's Section (To be answered by Owner or Occupant)
A. Explain any occupancy hazard changes since the previous inspection.
B. Describe fire protection modifications made since last inspection.
1 �_
C. Describe any fires since last inspection.
D. When was the system piping last checked for stoppage, corrosion or foreign material?
E. When was the dry- piping system last checked for proper pitch?
F. Are dry val . adef atel pr tect• om freezing? „,, �,/ ^� /j
Signature ./ /� ' Title 't'i(1� Date �0 ` -1�3 3
Inspector's Section (All responses reference inspection) NA = NOT APPLICABLE
1. General
a. Is the building occupied? gYes ❑ No
b. Are all systems in service ?'es ❑ No
c. Is there a minimum of 18 in. (457 mm) clearance between the top of the storage and the sprinkler deflectors ?Yes ❑ No
d. Does all electrical heat tape appear to be satisfactory? ❑ Yes ❑ No -NA
e. Does the hand hose on the sprinkler system(s) appear to be satisfactory? ❑ Yes ❑ No .6.4A
2. Control Valves (See Item 15.)
a. Are all sprinkler system control valves and all other valves in the appropriate open or closed position ?...Yes ❑ No
b. Are all control valves in the open position locked, sealed or equipped with a tamper switch ?,rYes ❑ No
3. Water Supplies (See Item 16.)
a. Was a water flow test of main drain made at the sprinkler riser(s) ?O_Yes ❑ No
4. Tanks, Pumps, Fire Department Connections
a. Are fire pumps, gravity tanks, reservoirs and pressure tanks in good condition and properly maintained? ❑ Yes ❑ No .S,NA
b. Are fire department connections in sa sfactory condition, couplings free, caps in place, and check valves tight ?g,,,Yes ❑ No ❑ NA
Are they accessible and visible? s ❑ No ❑ NA
5. Wet Systems
'a. Are cold weather valves (O.S. & Y.) .in the appropriate open or slosed position ?t .,Yes ❑ No ❑ NA
b. Have antifreeze system solutions been tested? ❑ Yes ❑ No .NA
c. Were the antifreeze test results satisfactory? ❑ Yes ❑ No g_NA
d. In areas protected by wet system(s), does the building appear to be properly heated in all areas, including.blind attics and perimeter areas
where accessible? Yes ❑ No ❑ NA Do all exterior openings appear to be protected against freezing ?J .Yes ❑ No ❑ NA
6. Dry Systems (See Items 11 to 13.)
a. Are dry valve(s) in service ?.tes ❑ No ❑ NA
b. Are the air pressures and priming water levels in accordance with the manufacturer's instructions ? ❑ No ❑ NA
c. Has the operation of the air or nitrogen supplies been tested ?n -Yes ❑ No ❑ NA Are they in service? B.Yes ❑ No ❑ NA
d. Were low points drained during this inspection? ❑ Yes ❑ No ANA
e. Did quick -opening devices operate satisfactorily? ❑ Yes ❑ No A-NA
f. Did the dry valve(s) trip properly during the trip pressure test? 6..Yes ❑ No ❑ NA
g. Did the heating equipment in the dry-pipe valve room(s) operate at the time of inspection? ❑ Yes ❑ No IES,NA -
7. Special Systems (See Item 14.)
a. Did the deluge or pre -action valves operate properly during testing? ❑ Yes ❑ NQ NA
b. Did the heat - responsive devices operate properly during testing? ❑ Yes ❑ No .Q NA
c. Did the supervisory devices operate during testing? ❑ Yes ❑ No AS.NA
8. Alarms
a. Did water motor(s) and gong(s) test satisfactorily? ❑ Yes ❑ No g.NA -
b. Did electric alarm(s) test satisfactorily? Yes ❑ No ❑ NA
c. Did supervisory alarm service test satisfactorily ?g. -Yes ❑ No ❑ NA
9. Sprinklers
a. Are all sprinklers free from corrosion, loading or obstruction to spray discharge? ,Yes ❑ No
b. Are sprinklers less than 50 years old? (Older sprinklers require sample testing) Yes ❑ No
c. Are quick response and residential sprinklers less than 20 years old? (Older sprinklers require sample testing) I .Yes ❑ No
d. Is stock of spare sprinklers available? 6-Yes ❑ No
e. Does the exterior condition of sprinkler system appear to be satisfactory? 6 ❑ No
f. Are sprinklers of proper temperature ratan. : their locations? B- es ❑ No
10. Explain any "No” a .: ' ers and c. ments:
Signature: -11 ��! ✓�/ Date: // P
Printed 8/88 By National Fire Sprinkler Association, Box 1000, Patterson, NY 12563
24 ;:' ".
ST. PAUL, i' ✓i;:VNE3Q' TA 5511 3
SIJBSCRI BER'S COPY
systems i •
Inspection Report _.rt470;! WMAIMAW.
,-y/ No. _ ,...'.,.
- Y
11 . Date dry pipe valve trip tested (control valve p rtially open) // � �i i2 (ee rip Test Tale w hich o l l lo ow .) ' 1 `'U�
12. Date dry-pipe valve trip tested (control va(,ve�fj�illy open) i (See Trip Test Table which follows.)
13. Date quick- opening device tested / / (See Trip Test Table which follows.)
DRY VALVE TRIP TEST TABLE C.O
lin24 iL
MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO.
DRY PIPE Time to Trip Water Air Trip Point Time Water Reached Alarm Operated
OPERATING Thru Test Pipe Pressure Pressure Air Pressure Test Outlet Properly
TEST MIN. SEC. PSI PSI PSI MIN. SEC. YES NO
Without
Q.Q.D. e l ib / 3 K.
With
Q.O.D.
14. Date deluge or preaction valve tested iti, ` (See Trip Test Table which follows.)
TRIP TEST TABLE
Operation G PNEUMATIC O ELECTRIC ❑ HYDRAULIC
Piping Supervised 0 YES 0 NO I Detecting media supervised OYES ONO
DELUGE & Does valve operate from the manual trip and /or remote control stations ❑YES ONO
PREACTION
VALVES Is there an accessible facility in each circuit for testing Method of testing•circwts
OYES ONO
Does each circuit operate Does each circuit Maximum time to
MAKE MODEL supervision loss alarm operate valve release operate release
YES NO YES NO YES NO
15. See Control Valve Maintenance Table.
Control Valve Maintenance Table Explain
Abnormal _
Control Valves Number Type Open Secured . posed Signs Condition
City Connection Control y :� �r qq ��
.-- Valve / e5- ,, 1 / /l/," ,> ��
.- �
.1 Valves �� � �% /��L./f/ /PPQ / - - 4 J �,ri ✓�!
Pump Control Valves IMIIIIWAIMEMMIIIIIIIIIMISIMINIF
Sectional Control Valves weirl� a rt�� . ,79/7/ ,,Vh f:
System Control Valves M Kr' � I MIi ,� ,Q J ,�
Other Control Valves iNZ���F� / i ��,�Al�'�,�,,W
L - . ,_ - - - — i
16. Water Flow Test at Sprinkler Riser /
Water Supply Source: City Tank Pump
Date Test Pipe Size of Static Residual
Location Test Pipe Pressure (Flow)
Pressure
Last Water Flow Test
This Water Flow Test /0 �} / 3 q-- /j W 7 /C i / / / r�
0
J 03,„1- 9 ss
17. Explain any "No" answers and comments:
•
18. Adjustments or corrections made during this inspection:
19. Although these comments are not the re . t of . engineering review, the following desirable improvements are recommended:
Signature: -.1 . � ' Date // ���`�
Printed 1/83 By National Fire Sprinkler Association, Box 1000, Patterson, NY 12563
SUBSCRIBER'S COPY