Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2003-11-05 Viking Automatic Sprinkler Co. Report of Inspection
e , , 4 STREET ° . I TA 55117 . (1100)-2294263 AUTOMATIC SPRINKLER co. 1 fat 10 • - .s SHEET t F 2 - Use separate sheet for each braiding inspection REPORT PECTION MINNESOTA LICENSE NO. C00005 1 SIN LICENSE NO. 265989 REPORT TO 0A J X v14n BUILDINU TION STREET Ci1e2Oritf O ; , a I 4111:0 s INSPECTOR, CITY & STATE K " i t . - :rte DATE DATE // > s7 Ottner's Section (To be answered by Owner or Occupant) ""` "' A. Explain any occupancy hazard changes since .the previous inspection: B. _ Describe fire protection modifications made since last inspection. C. Describe any fires since last inspection. D. When was the system piping last checked for stoppage, corrosion or foreign material? E. When was the dry- piping system last checked for proper pitch? F. Are dry valves adequately protected from freezing? Signature Title Date Q Inspector's Section (All responses reference current inspection) NA =NOT APPLICABLE 1. General a. Is the building occupied? es ❑ No b. Are all systems in service? [7 Yes ❑ No c. Is there a minimum of 18 in. (457 mm) clearance between the top of thejtorage and the sprinkler deflectors? ❑ Yes ` I,�4o d. Does all electrical heat tape appear to be satisfactory? ❑ Yes ❑ No A 1 e. Does the hand hose on the sprinkler system(s) appear to be satisfactory? ❑ Yes ❑ No. NINA 2. Control Valves. (See Item 15.) a. Are all sprinkler system control valves and all other valves in the appropriate open or closed .. sition? P Yes ❑ No b. Are all control valves in the open position locked, igabal4Lequipped with a tamper switch? es 0 No 3. Water Supplies (See Item 16.) a. Was a water flow test ofmain drain made at the sprinkler risers) ?Pi'es ❑ No 4. Tanks, Pumps, Fire Department Connections a. Are fire pumps, gravity tanks, reservoirs and pressure tanks in good condition and properly maintained? ❑ Yes ❑ No )4A b. Are fire department connection m satisfactory condition, couplings free, caps in place, and check valves tight)O Yes ❑ No ❑ NA Are they accessible and visiblYes ❑ No ❑ NA 5. Wet Systems a. Are cold weather valves (O.S. & Y.) in the appropriate open or . esed position? Yes ❑ No ❑ NA b. Have antifreeze system solutions been tested? ❑ Yes 0 No /I ' A c. Were the,antifreeze test results satisfactory? 0 Yes ❑ No NA d. In areas protected by wet system(s), does the buildigto be properly heated in all areas, including d attics and perimeter areas where accessible $Yes ❑ No ❑ NA Do all exterior openings appear to be protected against freezin Yes ❑ No ❑ NA 6. Dry System (See Items 11 to 1 a. Are dry valve(s) in servi es ❑ No ❑ NA b. Are the air pressures and priming water levels in accordance with the manufacturer's instructions7)Yes No ❑ NA c. Has.the operation of the air or nitrogen supplies been tested?)�Y ❑ No ❑ NA Are they in service? Y ❑ No ❑ NA d. Were low points drained during this inspection? ❑ Yes ❑ No 1A e. Did quick - opening devices operate satisfactorily? ❑ Yes ❑ No �TA f. Did the dry valve(s) trip properly during the trip pressure test'A'Yes ❑ No ❑ NA g. Did the heating equipment in the dry-pipe value room(s) operate at time of inspection ? ❑ Yes ❑ No TA 7. Special Systems (See Item 14.) / a. Did the deluge or pre-. • 'o - v 7 • :. . to properly during testing? ❑ Yes ❑ No ❑ NA b. Dici the heat - responsi • rate properly during testing? ❑ Yes ❑ No ❑ NA c. Did supervisory devi . uring testing? ❑ Yes ❑ No ❑ NA 8. Alarms a. Did water motor(s) and gong(s) test satisfactorily? ❑ Yes ❑ No 11A b. Did electric .alarm(s) test satisfactoryla Yes ❑ No ❑ c. Did supervisory alarm service test satisfactory? ❑ Yes / '9 'No ❑ NA .-1Q 9, Sprinklers a. Are all sprinklers free from corrosion, loading or obstruction to spray discharge ?es ❑ No b. Are sprinklers less than 50 years old? (Older sprinklers require sample testing),�Yes ❑ No c. Are quick response and residential sprinklers less than 20 years old? (Older sprinklers require sample testingYPYes ❑ No d. Is stock of spare sprinklers available ?¢ 'Yes ❑ No e. Does the exterior condition of sprinkler system appear to be satisfactory TfAres ❑ No f. Are sprinklers of proper temperature rating +r their locations ? es ❑ No 10. Ex. ain any "N,,, : wer and .,� � . 1 ts: e l� f '" t .ten..; ?'. Signature: s :2 H �V "`r;, 14C \"? Date: /1(//'S�7_ 1301 L'ORJENT,STREET * STpdL, MINNESOTA 55117 (65, j8&3300 • (800 )-229 -62613 AUTOMATIC SPRINKLER CO. FAX: (651) 558 -3310 SHEET - Use separate sheet for each system inspection System No. )r Descriptioniif maniple ms l ,SF ,... . ,; JJ . 11 ' Date dry-pipe valve trip tested (control valve part open) f � . ley ( S _Tr Test T N�h A 40 +, 12. D " iii valve trip tested (control vale 1y open) ''� (See Ti er Test Table which follows) 13. Da�tpuck- device tested f Al (See Thy Antr - Wiadl " ) DRY VALVE i TRIP TEST TABLE Q.O.D: btAxe MODEL SERIAL NO. MODEL SERIAL NO. DRY PIPE Time to Trip Water Air Trip Point Time Wider Reached Alsmt Operated OPERATING Thru Test Pipe' Pressure pressure Air. Pr ees ure Tilt Outlet Property TEST W ' MR . SEC PSI PSI . PSI MIN. SEC. YES Q.O.D. j ... 7 . a �� 140 Q.O.D. ''�._._ i -' . ° Id $ate deluge or reaction 'valvv'tested - - 1 rte' - TRIP TEST TABLE . Operation ❑ PNE ❑ ELECTRIC ❑ HYDRAULIC • Piping Supervised ❑ Y-_ . ❑ NO 1 Detecting media supervised ; ❑ YES ❑ NO DELUGE & Does valve operate from the manual ■ and/or remote control stations ❑ YES ❑ NO PREACTION Is there an accessible facility In . • ;mutt for testing Method of tesanitclrouits VALVES ❑ YES ❑ NO Does each circuit operate Does each circuit Mtudrnum time to MAKE • 'EL supervision alarm_ operate vaive release operate release ;,YES' NO YES NO YES NO 151,_ See control Valve Maintenance Table. i Control Valve Maintea ce . Ted Control Values Number Type Open surd closed eons Can Oily Cor eetilin Contra Tank coup Valves , Tpnlp„Con/Int V; es Sectional Centre. es 111101111:111/4,21111FAIMIIIIIINIIIMIIM System Control Valves 1116•� Nik21111111L21111S'M111i Mier Control Valves ; :,, F . Y 1. ®1111 , • Kitchen Control Valve 11111111111 NIM111®111011 -- 1C_ W$Ia _Flow Test at Spr , r inkle Riser w - ; eater supply Sr a4: ° . ; , - � _ ' qty .. _ ; Date Test Pipe. : Size or i Static Residual Location Test Pipe Pressure (Flow) Pressure Last Water Flow Test )p/ /S �,? ` its 2 This Water Flow Test 9+ ,,7 e 17. Explain any "slo answers and comments: - r r iir .cor rect- . d this . ipspecti©n .�1 mss' ► K ,F1: 1 . �e....;x. -iar Yid 19.. Although these comments are not the result of an engineering re iew the following desirable improvements are recommended: f 't f*» sa? F/f A1• r Ali • ie..J L «n1 A16 /1. I .S GI Ai r E S na tire: / D ate. . � ''