HomeMy WebLinkAbout2002-04-04 NAC Planning ReportPLANNING REPORT
FILE NO: 798.02 — 02.09
BACKGROUND
NORTHWEST ASSOCIATED CONSULTANTS, INC.
TO: Kimberly Kamper
FROM: Cynthia Putz -Yang 1 Scott Richards
DATE: April 4, 2002
5775 Wayzata Boulevard, Suite 556, St. Louis Park, MN 55416
Telephone: 952.595.9636 Facsimile: 952 595.9837 planners@nacplanning.com
RE: Oak Park Heights — Andersen /St. Croix Mali: Planned Unit
Development Amendment
SC Mali LLC have requested a planned unit development amendment to allow
improvements at the St. Croix Mali. A reduction of two parking stalls from the required
number has also been requested, which requires a conditional use permit.
In 1999 the Kmart store space was converted to office space for Anderson at the mall.
Except for Herbergers and limited retail tenants, the remainder of the mall is now
proposed for Andersen office use.
The following list describes applications that were previously approved for the St. Croix
Mali:
• 1979 City approved original mall PUD.
• 1985 City approved a Conditional Use Permit for a temporary bank drive -
through facility.
• 1987 City approved PUD amendment to allow for expansion of the K -Mart and
other mall and site changes.
• 1989 City approved a PUD amendment for a major remodel of the center.
Current facade and site plan was based on this approval.
• 1990 Sign plan for the upper mall was approved and made effective on
September 1.
• 1992 City approved a PUD amendment to allow for the theatre expansion.
• 1992 City approved a change to sign plan for a monument business sign on
Osgood Avenue.
O 2001 City approved a PUD amendment and Design Guidelines review for Lower
St. Croix Mall to change facade and signage.
Attached for reference:
Exhibit A: Site Information Plan
Exhibit B: Perspective Drawing
Exhibit C: Partial Demolition Plan
Exhibit D: Detail Plan of Courtyard
Exhibit E: Elevations
Exhibit F: Project Narrative
ISSUES ANALYSIS
Zoning. The property is zoned 13-2, General Business. Retail and office uses are
permitted within the B-2 District. The St. Croix Mall was originally approved as a
Planned Unit Development in 1979; therefore, a PUD amendment is required before
any site or building changes can be made to the property.
Proposed improvements. The following improvements are proposed:
O 4,385 square foot enclosed computer deployment/receiving area
O Exterior seating area for proposed interior employee cafeteria
• Exterior courtyard
• Partial covered parking and walkway canopy
• New entry and maintenance area canopies
O Entry signage at relocated facility entry
O Demolition of existing retail exterior entry pavilions
Phasing of Mali Improvements. Only the improvements listed above are ro osed at
p p
this time and a phasing plan for improvements has not been submitted. The City should
work with Anderson Corporation on a phasing plan for future site improvements. City
staff would like to see the following improvements made at the mall over time:
O Parking improvements including new striping, curb islands, and landscaping.
• Removal of the parking lot access to 57 Street.
O Trail construction along the south property line and connection to Swagger Park
to the west as identified in the City's Park and Trail Plan.
O Removal of the pylon sign structure in the northwest corner of the site.
O Removal of the monument sign on Osgood Avenue.
O Bring parking lot light fixtures into conformance with City standards.
Anderson /St. Croix Mali Report
Page 2
Use
Floor Area
Ordinance
Requirement
Required
Spaces
Proposed Spaces
Retail
85,700 x .9 = 77,130
1 per 200 square feet
386
Office
217,219 x .9 = 195,497
3 + 1 per 200 sq. ft.
980
Total
272,627
1,366
1,400 — 36 = 1 ,364
Parking. As shown in the following table, 1 ,366 parking spaces are required and 1 ,364
parking spaces are proposed. A reduction in parking may be allowed by conditional use
permit. We recommend approval of the conditional use permit because the number of
proposed spaces is very close to the number of required spaces, and the applicant has
estimated that up to 700 Andersen employees will be located at the site, which is much
Tess than 980 spaces required for the office use.
Building Materials /Design Guidelines. The application narrative explains that
proposed exterior building finishes are a mix of materials selected to reduce the mass of
the existing structure and to complement the existing rockface masonry. Proposed
materials are illustrated on the elevations and include pre - finished corrugated metal and
Andersen "Fibrex" pre - finished cladding. Proposed canopies also help to break up the
mass of the building and are consistent with the City's Design Guidelines. The canopy
in the receiving area is mostly within an Xcel Energy easement and is therefore subject
to review and approval by Xcel Energy.
signage. The existing retail exterior entry pavilions are proposed to be demolished and
new entry signage is proposed at the northwest corner of the building as shown on the
elevations. Minor signage is also proposed for the new south employee entry. New
signage is proposed to be pin-mounted black anodized aluminum and will not be
illuminated. Overall, the signage area for the mall is being reduced. The proposed
signage will be incorporated into the approved sign plan for the mall.
Landscaping 1 Green Space. The area of green space is being increased and
landscaping is being added by converting part of the parking lot south of the building
into a landscaped courtyard.
Lighting. Staff has identified a small number of nonconforming wall lights. The
applicant has agreed to retrofit the building wakk lights to be full cutoff.
Refuse. A trash area is currently in place and no changes are proposed. Additional
dumpsters may be placed on site temporarily for construction purposes.
Utilities. Any changes to existing utilities or construction over existing utility service
lines is subject to review and approval of the City Engineer.
Construction Schedule. The project narrative states that the improvements will be
completed sequentially, in coordination with various interior construction phases.
Completion of all proposed improvements is scheduled for December 2002.
Anderson /St. Croix Mall Report
Page 3
CONCLUSION 1 RECOMMENDATION
The application generally complies with City regulations and is a reinvestment in an
existing development, which is consistent with City goals. We recommend approval of
the PUD amendment and conditional use permit to allow reduced parking subject to the
following conditions:
1. The portion of the receiving area canopy within the Xcel Energy easement is
subject to review and approval by Xcel Energy.
2. All mall building wall light fixtures must be retrofitted to be full cutoff.
3. Grading and drainage issues are subject to review and approval of the City
Engineer and review of the applicable watershed authority if required.
4 Any changes to existing utilities or construction over existing utility service lines is
subject to review and approval of the City Engineer.
pc: Kris Danielson
Anderson /St. Croix Mali Report
Page 4
;I!
z
O
F
I.L
2
0
o
z
W E
�- J
z Q
u z
w 111
a0
W
L
'HMO
t`3V J'z z k k ! C J ]! � f C' ; s t \jf , •,.ivd 'i�'U♦!'l:?L,! i _u J rF♦
1
N11111111111111
za
p4 4
A H
x
F.
rf
1,1
q"
Dia
r_f ■ i :.I z F =� JE kJ 'E od
A
1
,$)
w
a"
S ao
co
y 4
3
r
N ,
\ 1 1 , // ; ,.„ // /1/ ,
I 1 I /
, . y / /
x 1 / / 1 -� �_ / , , I /
a
t J . 1/ / A-
- 9 / 1
1
C , ), I \ j
f 1
,,, , ,_,-0 , _\\2::, ,4,,,,
\ , ,,-...„,, \,,,„ ,,„
1 . iv 1
1
\\\ \ ‘
--, \
. \ \\ \ \ \ \\\\\\\ \
\ \\ \ \ \ V
, \\\ \ \ '<:\,., \ , ‘,...,\ „.„ \&.„. ,-:.' .„-I., ..1",„.„, \\.\\:„..,\,,,,,,,, , , \-\\ \,,,,\\\„ \--:,;;„
A
8
$`0. �' 1 E ! i ! _ 1'1C . 1 L'i z z.r,E i irj �f iu 'I! ' i 'I '? ? i ! )1 _
3
1
t a.
ILI
!Pr: LAP ',id
1
c,,
es
Z
N
uJ
z
0
N
It
0
A40,,
.140
[NU
z
0
N
riv L Li H 6, 1) tVVmd vud
w
w
REQUEST FOR
PUD AMENDMENT
PROJECT NARRATIVE
Meyer, Scherer, Rockcastle, Ltd.
21 March 2002
SC MALL LLC
SHARED SERVICES CAMPUS / ST. CROIX MALL
OAK PARK HEIGHTS, MINNESOTA
ECIEDWEE
MAR 2 2 2002
1
EXHIBIT F
Applicant Information
Owner: SC Mali LLC
100 Fourth Avenue North
Bayport, MN 55003 -1096
Contact: Rebecca Maras
651.264.7856
rmaras@andersencorp.com
Architect: MS &R, Ltd.
119 North 2in St.
Minneapolis, MN 55401
Contact: Marc Partridge, AIA
612.359.3259
marcp @rnsrltd.com
General Background
Facing an urgent need for office space, Andersen Corporation commissioned MS&R to
"reinvent" an existing Kmart retail store at the St. Croix Mali, converting it for office use
in 1999. SC Mali LLC subsequently purchased the entire retail Mali. They are currently
designing the remainder of the Mali for Andersen office use, creating improvements in
efficiency, collaboration and identity in a Shared Services campus. Up to 700 Andersen
employees will be located at the site; several retail tenants will remain at the Mali for the
foreseeable future.
• Current Zoning: Planned Unit Development, (PUD). B-2 zone.
• Allowable use: Office and Retail are both allowed under the PUD.
▪ PUD Requirements: Requirements are the same as those in zone B -2 and City of
Oak Park Heights general zoning code and design guidelines.
• Acreage: 22.79 acres not including the Kmart parcel (3.88 acres)
Proposed Improvements
Exterior improvements to portions of the building and site, including:
• 4,385 sf enclosed computer deployment /receiving area
■ exterior seating area for proposed interior employee cafeteria
• exterior courtyard
• partial covered parking and walkway canopy
• New entry, maintenance area canopies
■ Entry signage at relocated facility entry; demolition of existing retail exterior entry
pavilions
SC Mali LLC
PUD Amendment Page 2
These improvements, in conjunction with interior renovation currently ongoing, are
expected to satisfy the requirements of Andersen Corporation for the foreseeable future.
No additional modifications or changes to site, vehicular circulation or amenity are
anticipated at this time.
Construction Schedule
The above improvements will be completed sequentially, in coordination with various
interior construction phases; completion of all proposed improvements is scheduled for
December 2002.
Proposed Building Finishes
New exterior building finishes are selected as a mix of materials to reduce the mass of the
existing structure and to complement the existing rockface masonry, consisting of:
▪ Prefinished corrugated metal
▪ Andersen "Fibrex" Prefinished cladding
See building elevations for distribution of materials.
Proposed Landscaping
Emphasis of the plan must be the perimeter of the site, the immediate perimeter of the
building, and public boulevard areas. Landscape criteria shall meet OPH zoning code
section 401.15.E.10 for plant size and spacing requirements.
See Landscape plan for distribution and species.
Proposed Signage
Exterior signage, mounted on the building exterior, is proposed for the relocated entry at
the northwest corner of the facility; minor signage is also proposed for the new south
employee entry. New signage will be black anodized aluminum, pin mounted, non -
illuminated letters.
Correspondingly, existing exterior retail mall "pavilions" will be removed to provide an
environment more consistent with an office facility, significantly reducing the overall
signage area for the facility.
See building elevations for sign location and extent.
Watershed District
Although no Watershed issues are anticipated, this submission is being sent concurrently
to the Middle St. Croix Watershed and Washington County Soil and Water District for
their review.
SC Mali LLC
PUD Amendment Page 3
Parking Summary
Gross Sq Footage Parking Req'd
Retail: 85,700 gsf 429 @ 5:1 000
Office: 217,219 gsf 1,089 @ 3 +1:200
Totals: 302,919 gsf 1,518
OPH Submittal Requirements
Please see drawings for the following:
1,366
Schematic drawing (Perspective Rendering)
Property Survey (flat Map)
Grading and drainage plan
Existing site conditions plan
Site development plan
Landscape plan
Signage plan
Lighting plan
Building plans, elevations
SC Mall LLC
parking required w/10% reduction
(exterior floor area dimensions of
building minus 10%)
1,400 existing parking
-36 parking stalls lost in proposed site
modifications
1,364 parking remaining after modifications
see A2
see Al
see A4
see A3
see Al
see A5
see A5
see A4
see Al, A4, A5
PUD Amendment Page 4