HomeMy WebLinkAbout2014-01-30 Summit Fire Protection Inspection Report SUMMIT FIRE PROTECTION 575 Minnehaha Ave.W • St.Paul,MN 55103 • 651-251-1880 3026 40TH Ave.NW • Rochester,MN 55901 • 507-280-0622 418 Great Oak Dr. • Waite Park,MN 56387 • 320-257-6390: 760 Liberty Way • North Liberty,IA 52317 • 319-665-4330 4208 Enterprise Circle • Duluth,MN 55811 • 218-740-4412 4353 NW Urbandale Dr. • Urbandale,IA 50322 • 515-867-2424 A SHEET 1 OF 2-Use separate sheet for each building inspection REPORT OF INSPECTION I MINNESOTA LICENSE NP 000751 IOWA'LICENSE NO.FP-036 JOB NIIIVI1ER „ , ?, � - t x � IIPECTLO 1 N ; ill 1 B I)INOfLOCA'I NV -'�" °'s ' "I EEme: �� a,;.,,rte ,.. R a , _ CITKi STATE OA igi., .r - de li t/r DATA t- ^f Owl's Section(to be answered by Owner or Occupant) A. Explain any occupancy hazard changes since the previous inspection: B. Describe fire protection modifications made since last inspection: C. Describe any fires since last inspection: D.-Whe ills-fheisystem �... e-� : «.,. 4 P,..— —r 3 w :;,+rig_„, . l ,;:,;. ,.- - , - .— . "I :'. checkedl`or proper.°' h? F. Are dry vall. i-•uately p a ted from freezing? ' ^, ;. Sil £/ '/ Title Date JS pector's Section(All responses reference current inspection) NA=NOT APPLICABLE �1. General a.Is the building occupied9r�(qes,' D No b.Are all systems in service?p res❑No c.Is there a minimum of 18 in.(457 mm)clearance between the top of the storage and the sprinkler deflectors?lakes D No . d.Does the hand hose or standpipe on the sprinkler system(s)appear to be satisfactory? DYes U NoliPNA 2. Control Valves(See Item 15.) l' a.Areal.sprinkler system control valves and all other valves m the appropriate open or closed position?)Fast'es 0 No 1.." ' b.Are all control valves m the open position lock equipped with . -a .pe i'• ,' Wes O'No 3. .Tanks,Pumps,Fire Department Connections a.When was fire pump last tested for performance? f" - '. b.Are fire pumps,gravity tanks,reservoirs and pressure tanks in good condition and properly maintained? DYes CI N901CFNA c.Are fire department connections in satisfactory condition,couplings free,caps in place,and check valves ti9es Cl No ©NA Are they accessible and visible? es U No ❑NA 4. Wet Systems a.Have antifreeze system soluti been tested? DYes U No NA b.What temp is antifreeze? k c.In areas protected by wet system(s),does the buildin 'pear ,. be properly heated in all areas?/ D No O NA 5. Dry System(See Items 11 to 13) a.Are dry valve(s)in service? DYes n No D NA b.Are the air pressures and p . .,_ -r l= -is in accordance with the manufacturer's instructions? DYes CI No UNA - r•.- • the /, n •••_en dies been tested? DYes la No DNA Are they in service? DYes D No DNA' e Did quick opening devic. tr.t s• . duly? DYes .• No • NA ` , ' , f.Did the dry valve(s)tri• •ro. y 1 el e trip pressure test? DYes D No D NA g.Did the heating equipment in •. a ' -pt• valve room(s)operate at time of inspection? DYes D No D NA 6. Special Systems(Star 14.) a.Did the deluge or pre-action valves •, properly during testing? DYes U No D NA b.Did the heat-responsive device o . o.-rly during testing? DYes D No DNA c.Did supervisory devices oper. .4.d -I . ting? DYes D No DNA d.Did flow for kitchen hood sy' s. • gas or electric? DYes D No D NA 7. Alarms a.Did water motor(s)and:gong(s)test satis actorily? DYes D No A b Did electric alarms testsatisfactonl s C1 N DNA . Y? ` c Did supervisory alarm service hest satisf torily?Mes U No Ca NA `d Did tamper switelies test satisfactorily? r•`'s L1.No D NA l 8, .Sprinklers a.Areall sprin `..then fr • • •a . loading dr to spray'f *! `} es U No' b.Are sprinklers-less than 50 years old (• •'r sprinklers regniffitStnnPle testing 1 es 16 c:Are quick response and r'e ential spas less than 20 years old?(Older spnnklersrer ire sample testa} 'f es D No 0-NA ;, d.Is stock of spare sprinklers available? es CI No e.Does the exterior condition of sprinkler syste. .-ar to be sat 4 tory?76'es D No '`�`' , j f.Are sprinklers of. u. mperature. ..' ,•' e locations? s D No - ' g.Is location . - recall- h- . .• 0 J tne" E-b; Date: , 1111111 SUMMIT FIRE PROTECTION 575 Minnehaha Ave.W. • St.Paul,MN 55103 • 651-251-1880 3026 40th Ave.NW • Rochester,MN 55901 • 507-280-0622 418 Great Oak Dr. • Waite Park,MN 56387 • 320-257-6390 760 Liberty Way • North Liberty,IA 52317 • 319-665-4330 4208 Enterprise Circle • Duluth,MN 55811 • 218-740-4412 4353 NW Urbandale Dr. • Urbandale,IA 50322.• 515-867-2424 SHEET 201z 2-Use - . sheet for east Fystem inspection Type of System 1 ott Name A at is h /r.JS. { How Many?' '� 3 ' .f` .k 'r ` r .} y' t 1 r�r; =?F a 3' --.,-,\::::'''''.4*'''''.. ; r a r}' s 3 CSg� $pg�tte c q fV .� I Y pt 9 `Masted(' 1 v. i.ve�y oped ° (see Trip'Test`.able which follows) i • Date tley Pipe valve trip tested(control valve fully open) (see Trip Test Table which follows) ,*, Y ' 11, Date quick-opening device tested (see Trip Test Table which follows) DRY VALVE TRIP TEST TABLE Q.O.D. MAKE MODEL .4. NO. MAKE MODEL SERIAL NO. DRY PIPE Time to Trip Trip Point me Water Reached Alarm Operated OPERATING '!firs Test Pipe ,s Water Pressure Pressure Time Pressure Test Outlet Properly TEST Min. Sec. PSI PSI PSI Min. Sec. Yes No ,.-, -. ;� W. .,�__..-*. _. A._: i.,.� .,-•- .-+-„ "°`.�:-. .,,. r --4111c,,-_:x -+16'- ,z' . 12. 'Date deluge or preaction valve tested A)/4 -- (see Trip Test Table which follows) TRIP TEST TABLE Operation ❑Pneumatic ❑Electric D Hydraulic • Piping Supervised ❑Yes ❑No ~ Detecting Media Supervised ❑Yes ❑No DELUGE 81 Does valve operate from the manual trip and/or re r '. ataaons? ❑Yes ❑tilo VALVES r.. ,t `�there an accessible facility for each�^ for testYag� ©Y�*' �No _Method of Testing Grrcurts:� •.; ; - ^' { t> c CI.6BS.t atm1• a Operate Release? " MOper�r Relepse1 i'.`:. r DPY'S 13t Does ❑Yes 0 N 'T3 Yes 0 N- DYes 0 N 13. See Control Valve Maintenance Table CONTROL VALVE MAINTENANCE TABLE °x CONTROL VALVES NUMBER SIZE&TYPE OPEN SECURED CLOSED SIGNS EXPLAIN ABNORMAL CONDITIONS 'v' City Connection Control Valve Jockey'Control Valve Pump.Control Valves Additional Punip Control Valves Sectional Control Valves S y s t e m C o n t r o l V a l v e s _ ' Other Control Valves Kitchen Control Valves Wider Flow Test at Sp', Water SuPP1Y t Well lank Pump A ` t - Y D,'-'51'./.*._:... '!' Al!tlA� DIFFERENTIAL 4 DAIK TEST EVE LOCATION SIZE OF 10-6,1 iii .. ki *Test fX _ t P1 6M1Vi ,, f i E y'"�to'.answer sad - ,„• . Y 2 fi if fofiF. w Print Name •�/l 1 f) Date 1j�"'-'7