HomeMy WebLinkAbout2003-04-22 Bayport Fire Department Inspection Report Inspection Report Bayport Fire Department•301 2nd Avenue North • Bayport, MN 55003• (651) 439-6992 Date O Time Property Address ` , Phone 9^ t-rte .. ( Co - -k ' `# 3 Bu'-' .:;..t.--rty Name Correspondence To � IAAP (4,5 S Occupancy Class Const.Type Const.Year No.of Stories Sq.Ft.Floor No.of Occupancies Inspec.Type Ownellimpe iloeyl*/ Address City State Zip V-Does Not Meet Requirements NV-Appears to Meet Requirements NA-Not Applicable (See Additional Instructions On Back) ✓ NV NA 1. Exterior V NV NA 4. Storage V NV NA 8. Sprinkler Systems ❑ /t CI a.Fire Lanes marked/unobstructed ❑ 'il� ❑ d.No combustible storage under ❑ N% CI b.Controls readily accessible y ❑ ❑ b.Address visible unprotected stairways ❑ ❑ c.Valves locked open or CI ❑ c. Fire hydrant(s)accessible ❑ ❑ lid e.Storage maintained 2'below supervised ceiling(unsprinklered) CI CI d.Combustible accumulation(s) ❑ 17 d.Properly serviced acceptable ❑ ❑ f. Storage maintained 18"below El ' ❑ e.Heads in good condition sprinkler heads ❑ ❑ e.F.D.lock box present ❑ NU ❑ f. Wrench/spare heads present Ire CI yl ❑ g.Aisles maintained-44"min. ❑ X ❑ f. F.D.connections visible/good ❑ ❑ h.Rubbish,oily rags,waste I condition material properly stored V NV NA 9. Fire Alarm Equipment ❑ ❑ a.Detectors(smoke,heat)properly ✓ NV NA 2. Exit Features V NV NA 5.Flammable/Comb.Liquids installed ❑ h ❑ a.Adequate number of exits 17 CI a.Proper quantities ❑ ❑ b.Pull stations properly installed ' ❑ XL ❑ b.Exits,aisles and corridors ❑ b.Proper storage/dispensing CI ❑ c. Detectors needed free of obstructions CI CI XCI c. Exits openable from inside ❑ V ❑ c. No sources of ignition ❑ d.Properly serviced/maintained El 17❑ A ❑ d.Exit hardware present and CI V:1*V:1* CI d.Adequate ventilation e.Tests/drills conducted operational El V. ❑ e.Proper electrical equipment ❑ CI e.Exit signs present V NV NA 10.Other Fire Protection Equip. ❑ st ❑ f. Exit illumination adequate V NV NA 6.Utility,Mechanical,HVAC ❑ ' ❑ a.Standpipes needed ❑ CI g.Emergency lighting present and CI (5a CI a.Relief valve present on boilers 171 ❑ b.Standpipe/hose in good cond. operational and water heaters ❑ Cl c.Adequate coverage ❑ ❑ ❑ h.Occupant load posted and ❑ lz ❑ b.Shut off valve present on gas ❑ lel ❑ d.Hood system-fuel shutoff present maintained appliances ❑ v, ❑ e.Properly serviced/maintained ❑ W ❑ i. Interior finish acceptable ❑ 3IC ❑ c.Approved piping/connectors ❑ jiQ CI j. Stairway ID present \ and appliances used ❑ ❑ d.Proper venting present and in V NV NA 11. Electrical good condition ❑ AlEn ❑ a.Appliances/fixtures in good ✓ NV NA 3. Construction Features condition CI CI e.Combustion air supply present ❑ X ❑ a.Fire separations present CI Vt ❑ f. Adequate clearances between CI t I ❑ b.Overcurrent protection present and maintained combustibles and appliances ❑ sk ❑ c. Proper wiring/connections ❑ 114 ❑ b.Openings in fire walls sealed ❑ x ❑ g.Clean ducts and filters ❑ Ci4 ❑ d.Extension cords not used in ❑ V ❑ c. Rated fire doors present and place of fixed wiring operational(closing/latching) ✓ NV NA 7. Fire Extinguishers C7 �( ❑ e.Proper use of wiring and CI ,k CI d.Vertical openings acceptable equipment ❑ t ❑ a.Readily accessible ❑ i< ❑ f. 30"clear access to panels V NV NA 4.Storage ❑ Ul CI b.Proper number and type provided ❑ 6 CI a.Storage neat and orderly ❑ CI c.Suitable location CI b.No combustible storage in CI CI d.Properly serviced/maintained V NV NA 12. Miscellaneous boiler or mechanical rooms ❑ kr ❑ a.Proper storage of compressed ❑ A ❑ c. No combustible storage in V NV NA 8.Sprinkler Systems gases unprotected attics ❑ ❑ a.Adequate coverage CI CI b.Interior decorations acceptable or flame retardant ❑ ❑ c. No smoking provisions enforced Coo�mme`' �, n n �+ —:�E- �C7*seS = iyou7- t16 l�S ui . `i Tom-Cttioh Q. Re-Inspect Date apt. Pr pert r/'>.resentative Ail NOTICE TO THE OWNER, OCCUPANT, LESSEE, OR AGENT OF THE PROPERTY WHOSE ADDRESS IS LISTED ON THE REVERSE SIDE: In accordance with Minnesota Statutes 299F.011, an inspection of your property was conducted for the purpose of fire and life safety.At the time of the inspection, certain conditions were observed which do not meet minimum requirements of the MN Uniform Fire Code. Those items are checked in the first column, under V. A follow-up inspection will be conducted on or after the date listed on the bottom of the inspection report. The purpose of the follow-up inspection is to determine that any violations or deficiencies observed on the previous inspection have been corrected. Failure to comply with fire prevention requirements is a violation of state statute and/or municipal ordinance. There is a variance procedure provided by the statute. Thank you for your assistance with these fire prevention items. If you have any questions or need additional information, please feel fee to contact the Bayport Fire Department at 439-6992.